Omron Cordless Low-Frequency Therapy Device HV-F601T Series HV-F601T1-C









Popis
[Please read the instruction manual carefully]
[Generic Name] Home Low-Frequency Therapy Device
[Product Name] OMRON Cordless Low-Frequency Therapy Device HV-F601T Series
[Warning] • Do not use near the heart, chest, above the neck (including the head and mouth), genitals, or areas with skin disorders. Also, do not use in a manner that pinches internal organs. ▶ Risk of accident or poor health. • Consult a doctor before use if you: (1) People receiving medical treatment or who are experiencing physical abnormalities (2) People with malignant tumors (3) People with cardiac or cranial nerve abnormalities (4) Pregnant women or those who have just given birth (5) People with a body temperature of 38°C or higher (fever stage) (Example 1: During a period of severe acute symptoms (fatigue, chills, blood pressure fluctuations, etc.) Example 2: When feeling weak) (6) People with infectious diseases (7) People with skin sensory disorders or skin abnormalities (8) People with acute (painful) conditions such as spinal fractures, sprains, or muscle strains (9) People with a chronic (painful) illness (10) People who require rest (11) People with abnormal blood pressure (12) People with limb disabilities (13) People who cannot express themselves (14) People with sensory impairments due to severe peripheral circulatory disorders such as diabetes (15) People with low temperatures (16) People with poor circulation (17) People who do not see results even after using the device for a while (18) People with skin discomfort caused by the pads (19) People with metal implants ▶ Continued use may result in an accident or poor health. • Do not use for purposes other than treatment. • Do not use if the pad surface is chipped or damaged. • Do not use if the pad is chipped or damaged. • Doing so may result in an accident, malfunction, or breakdown. • Do not use with other treatment devices or ointments (including spray cans). • May cause nausea or illness. *Up to two OMRON Cordless Low-Frequency Therapy Devices HV-F601T Series (HV-F601T/HVF602T/HV-F601T1/HV-F601T1-C) can be used simultaneously. (These devices are the same even if the sales product codes are different.) • Do not allow individuals who are unable to express their own wishes or who require assistance to use the device alone. ▶ Failure to do so may result in accidents, injuries, or poor health. • Do not allow children to use the device, play on the device, or climb on it. ▶ Failure to do so may result in accidents, injuries, poor health, or malfunctions. • Do not use in humid areas or while bathing. ▶ Risk of severe shock. • Do not use while sleeping. ▶ Risk of malfunction. Furthermore, the device may malfunction. Furthermore, the pads may stick to unexpected places, causing ill health. • Do not use while driving a car or operating dangerous machinery. ▶ Strong stimulation may lead to accidents or malfunctions. • Do not bend or fold the pads forcefully. ▶ This may result in electric shock or an accident. • Do not use in areas where the use of wireless devices is prohibited, such as on airplanes or in hospitals. • Do not place the charger near (within 15 cm) anyone using a pacemaker or implantable cardioverter-defibrillator (ICD). ▶ The magnetic field generated by the charger may adversely affect these devices. • Do not repair or modify the device. ▶ This may result in fire, malfunction, or an accident. • Do not puncture the battery with a nail, subject it to impact, or disassemble or modify it. • Do not throw the device or battery into a fire or heat it. • Do not charge, use, or leave the device near a fire, in direct sunlight, or in other high-temperature locations. ▶ This may result in overheating, fire, or explosion.
[Contraindications/Prohibitions] • Do not use this product in conjunction with the following electrical medical equipment:
(1) Implantable electrical medical devices such as pacemakers
(2) Life-sustaining electrical medical devices such as heart-lung machines
(3) Wearable electrical medical devices such as electrocardiographs ▶ Doing so may cause these electrical medical devices to malfunction, resulting in serious injury or death.
[Product Specifications] Dedicated AC adapter: [Rated input] AC 100V, 50-60Hz, [Rated output] DC 6V 700mA Battery: DC 3.7V (Lithium-ion) Charging Time: Approximately 8 hours Number of Uses: Approximately 6 times (when fully charged) Service Life*: [Main Unit] Approximately 5 years, [Pad] Approximately 30 times (based on 30-minute use), [Charger] Approximately 5 years, [AC Adapter] Approximately 5 years (based on in-house data) *Based on standard usage (30 minutes of use per day, charging once every 6 days) Rated Output Voltage: Maximum approximately 50V Maximum Output Current: 10mA or less Frequency: 0.2-108Hz Maximum Pulse Width: [Low Frequency Course] 100μs, [Microcurrent Course] 2.5s Rated Time: 30 minutes Power Consumption: 0.5W Operating Environment: +10-+40°C / 30-85% RH (non-condensing) / 700-1060hPa, except for +5-+35°C when charging Storage Environment: 0-+40°C / 30-85% RH (no condensation) Weight: [Main Unit] Approx. 42 g, [Pad Medium] Approx. 17.5 g, [Charger] Approx. 61 g Dimensions: [Main Unit] Approx. 60 (W) x 72 (H) x 15.7 (D) mm [Pad Medium] Approx. 179.8 (W) x 79.4 (H) x 9.3 (D) mm [Charger] Approx. 80 (W) x 90 (H) x 23.5 (D) mm Operating Principle: Utilizing the nerve and muscle response to low-frequency electricity, a weak pulse current is applied below the skin surface, resulting in physiological effects that treat the affected area. IP Protection Rating: [Main Unit] IP22, [AC Adapter] IP21 Communication Method: Bluetooth® Low Energy Wireless Communication Specifications: Frequency Band: 2.4 GHz (2400-2483.5 MHz), Modulation Method: GFSK, Effective Radiated Power: <20 dBm Composition of Parts in Direct Contact with the Body: Acrylic Resin, Glycerin, Water Automatic Power-Off Specifications: The device will automatically turn off after 10 minutes in the following cases: • Treatment ends • Pads peel off from the skin • Treatment is interrupted
[Usage Precautions] • Immediately discontinue use if you experience any physical or skin abnormalities, such as eczema, redness, or itching. ▶ Consult a doctor and follow their instructions. • If you need to change pads to a different area during treatment, be sure to turn off the power before doing so. • Do not allow another person to change pads during treatment. • Do not use the device while the pads are in contact with metal objects such as belts or necklaces. ▶ Risk of severe shock. • Do not wear electronic devices (watches, pedometers, etc.) during treatment. ▶ The time and numbers may become inaccurate. • If the device stops working or if you notice any abnormalities, turn the power off immediately and contact the Omron Customer Service Center. ▶ Doing so may result in accidents, problems, or malfunctions due to overheating or short circuits. • Do not plug in or unplug the AC adapter or attach the pads with wet hands. • Do not attach pads to wet areas. • Doing so may result in electric shock or an accident. • When unplugging the AC adapter from the outlet, always hold the AC adapter by your hands, not the cord. • Doing so may result in electric shock or a short circuit, which may cause fire or malfunction. • Do not place metal objects such as coins or paperclips on the charger. • Doing so may result in electric shock or an accident. • Do not leave pads attached to the affected area. • Doing so may cause skin inflammation. • Do not use the pads on one area for long periods of time (more than 60 minutes). • Doing so may fatigue the muscles in the treatment area, leading to poor physical condition. • Make sure the device and pads are properly connected before use. ▶ Improper connection may result in electric shock, accidents, or malfunctions. • Attach the pads correctly. • Attach the pads so that the adhesive side does not touch the spine. • Do not attach pads to areas that are difficult to reach. ▶ Improper attachment may result in an accident or poor health. • Do not attach pads on top of each other. ▶ Treatment may not be carried out properly. • Do not attach pads to areas where deodorant sheets or sprays have been used to reduce sweating, where lotion or oil has been applied, where sweat is present, or where the area is not clean. ▶ The adhesive strength of the pads may decrease. • If the adhesive strength of the pads decreases, purchase new pads separately. ▶ Continued use may result in an accident or poor health. • Do not share pads with others. ▶ Risk of skin irritation. • When removing the device from the pads, press the pad removal button while lifting the device. ▶ Improper removal may result in an accident or malfunction. • Store the pads in the pad holder. • Always keep the pads clean. ▶ Improper storage may damage the pads. • When using this product, use only with the dedicated product. ▶ Doing so may result in an accident or malfunction. • Using this product near wireless LAN, microwaves, or other wireless devices may cause radio interference. If radio interference occurs and communication with your smartphone is not working properly, turn off unused devices or change their location to use them in an environment where radio interference is not present.
[Name of Manufacturer/Distributor] OMRON HEALTHCARE Co., Ltd. 53 Kunotsubo, Terato-cho, Muko-shi, Kyoto 617-0002 OMRON Customer Service Center TEL: 0120-30-6606 (toll-free)
[Purpose of Use or Effects/Efficacy] Relieves stiff shoulders, prevents atrophy of paralyzed muscles, and provides a massage effect. For general household use. Medical Device Classification: Specially Controlled Medical Device Medical Device Certification Number: 230AGBZX00089000 Unit Dimensions: Approx. 60 (W) x 72 (H) x 15.7 (D) mm Weight: Approx. 42 g